NPower Off-Grid Inverter
Key words:
Whatsapp/Wechat:
NPower Off-Grid Inverter
Product Description
The NPower series is a pure sine wave inverter that converts 12/24/48V DC to 220/230V AC. The product is based on full digital design and adopts technologies such as SPWM, voltage and current double closed-loop control and fully isolated inverter, so that the product has excellent electrical parameters and strong resistance to load impact. At the same time, the input adopts anti-surge design to meet the requirements of lithium battery surge limit and ensure the safe operation of the inverter; the chassis is designed with galvanized sheet, which has the advantages of high hardness and corrosion resistance; this product has high stability and appearance Simple, multi-protective, easy to install, easy to operate, etc.; suitable for AC loads such as household appliances, power tools, industrial equipment, electronic audio and video, as well as solar photovoltaic power generation systems, such as vehicle inverter application systems, solar RVs, solar households applications, solar yachts and solar power plants.
Features
• Using SPWM technology, pure sine wave output
• Adopt voltage and current double closed-loop control to enhance load capacity
• Input and output adopt fully isolated inverter technology
• The input adopts anti-surge design to meet the requirements of lithium battery surge limit and avoid inrush current caused by wiring or power-on
• Low output harmonics (THD≤3%)
• The output adopts excellent EMC design to avoid interference of connected equipment
• Output voltage 220/230VAC, frequency 50/60Hz can be selected by DIP switch
• Protection function: input reverse connection/overvoltage/low voltage, output overload/short circuit, high temperature
• The RS485 interface can be connected to the communication module, and the inverter can be started and stopped remotely and the operating status of the inverter can be monitored through APP or PC software.
• Through the mobile phone APP and PC software, the input over-voltage and over-voltage recovery voltage points can be set
• The inverter ID number can be set through the mobile phone APP and PC software to realize the monitoring of multiple inverters
• The chassis is designed with galvanized sheet, with high hardness and strong corrosion resistance
• Replaceable output panel: 220V national standard, European standard, Australian standard, multi-standard, terminal
• Local display unit displays system operating status (NP4000-22(T) and NP5000-42(T) only), and remote display unit can also be connected
• Easy to install, easy to operate, easy to maintain and repair
Technical Parameter
The marks ① / ② / ③ in the technical parameter table have the following meanings:
① The DC input is rated voltage, and the on-load power is 80% of the continuous output power (25°C);
② The DC input is rated voltage, and the load power is continuous output power (25℃);
③ The DC input is the rated voltage, and the maximum efficiency under different load power conditions.
Parameter |
NP260-11 |
NP260-21 |
NP600-11 |
NP600-21 |
Continuous output power |
260W@25℃, 200W@45℃ |
600W@45℃ |
||
Can withstand instantaneous impact power (5S) |
400W |
1200W |
1000W |
|
The output voltage |
110/120VAC (±5%) |
|||
Output frequency |
50/60Hz±0.2% |
|||
Output waveform |
Pure sine wave |
|||
Output harmonic components |
THD≤5%(Pure resistive load) |
|||
Load power factor |
0.2~1(Load power≤continuous output power) |
|||
Input rated voltage |
12VDC |
24VDC |
12VDC |
24VDC |
Input voltage range |
10.8~16.0VDC |
21.6~32.0VDC |
10.8~16.0VDC |
21.6~32.0VDC |
Rated 80% output efficiency① |
82.9% |
87.4% |
82.5% |
87.5% |
Maximum rated output efficiency② |
82.3% |
86.0% |
80.2% |
85.6% |
Maximum output efficiency③ |
89.6%(67W) |
90.2%(104W) |
90.7%(150W) |
91.9%(160W) |
Inrush current at input |
20A@25℃,VIN=12V |
20A@25℃,VIN=24V |
20A@25℃,VIN=12V |
20A@25℃,VIN=24V |
No-load current |
<0.3A |
<0.15A |
<0.67A |
<0.22A |
Static loss |
<0.3W@12V |
<0.4W@24V |
<0.3W@12V |
<0.4W@24V |
RS485 communication interface |
5VDC/250mA(Non-isolated communication) |
|||
Mechanical parameters |
||||
Input terminal |
M6 |
M8 |
||
Dimensions(L×W×H) |
365×212×97mm |
428×243×121mm |
||
Installation size |
220×193mm |
260×220mm |
||
Mounting hole size |
Φ7mm |
Φ9mm |
||
Net weight |
6.5kg |
6.4kg |
10.8kg |
10.2kg |
Parameter |
NP1000-11 |
NP1000-21 |
NP1000-41 |
Continuous output power |
1000W@25℃, 850W@45℃ |
1000W@45℃ |
|
Can withstand instantaneous impact power (5S) |
2000W |
||
The output voltage |
110/120VAC(±5%) |
||
Output frequency |
50/60Hz±0.2% |
||
Output waveform |
Pure sine wave |
||
Output harmonic components |
THD≤5%(Pure resistive load) |
||
Load power factor |
0.2~1(Load power≤continuous output power) |
||
Input rated voltage |
12VDC |
24VDC |
48VDC |
Input voltage range |
10.8~16.0VDC |
21.6~32.0VDC |
43.2~64.0VDC |
Rated 80% output efficiency① |
83.4% |
88% |
90.6% |
Maximum rated output efficiency② |
80.6% |
85.7% |
89.2% |
Maximum output efficiency③ |
92.2%(200W) |
93.4%(250W) |
94.3%(300W) |
Inrush current at input |
30A@25℃,VIN=12V |
30A@25℃,VIN=24V |
30A@25℃,VIN=48V |
No-load current |
<0.59A |
<0.33A |
<0.19A |
Static loss |
<0.3W@12V |
<0.4W@24V |
<0.7W@48V |
RS485 communication interface |
5VDC/300mA(Non-isolated communication) |
5VDC/250mA(Non-isolated communication) |
5VDC/300mA(Isolated communication) |
Mechanical parameters |
|||
Input terminal |
M6 |
M8 |
|
Dimensions(L×W×H) |
511×268×139mm |
452x268x139 |
|
Installation size |
300×245mm |
270x245 |
|
Mounting hole size |
Φ9mm |
||
Net weight |
16.1kg |
16.0kg |
14.0kg |
Parameter |
NP2000-11 |
NP2000-21 |
NP2000-41 |
Continuous output power |
2000W@45℃ |
||
Can withstand instantaneous shock power |
4000W |
||
The output voltage |
110/120VAC(±5%) |
||
Output frequency |
50/60Hz±0.2% |
||
Output waveform |
Pure sine wave |
||
Output harmonic components |
THD≤5%(Pure resistive load) |
||
Load power factor |
0.2~1(Load power≤continuous output power) |
||
Input rated voltage |
12VDC |
24VDC |
48VDC |
Input voltage range |
10.8~16.0VDC |
21.6~32.0VDC |
43.2~64.0VDC |
Rated 80% output efficiency① |
84% |
89% |
89.4% |
Maximum rated output efficiency② |
82.5% |
87.5% |
87.7% |
Maximum output efficiency③ |
90.8%(500W) |
93.9%(500W) |
93.9%(500W) |
Inrush current at input |
20A@25℃,VIN=12V |
20A@25℃,VIN=24V |
20A@25℃,VIN=48V |
No-load current |
<1.9A |
<0.5A |
<0.3A |
Static loss |
<0.6W@12V |
<0.6W@24V |
<1.8W@48V |
RS485 communication interface |
5VDC/300mA(Non-isolated communication) |
5VDC/300mA(Non-isolated communication) |
5VDC/200mA(Isolated communication) |
Mechanical parameters |
|||
Input terminal |
M10 |
||
Dimensions(L×W×H) |
554×393×175mm |
486×313×145mm |
|
Installation size |
350×372mm |
350×292mm |
|
Mounting hole size |
Φ9mm |
||
Net weight |
30.3kg |
28.1kg |
21.2kg |
Parameter |
NP2500-11 |
NP2500-21 |
NP2500-41 |
Continuous output power |
2500W@45℃ |
||
Can withstand instantaneous shock power |
5000W |
||
The output voltage |
110/120VAC(±5%) |
||
Output frequency |
50/60Hz±0.2% |
||
Output waveform |
Pure sine wave |
||
Output harmonic components |
THD≤6%(Pure resistive load) |
||
Load power factor |
0.2~1(Load power≤continuous output power) |
||
Input rated voltage |
12VDC |
24VDC |
48VDC |
Input voltage range |
10.8~16.0VDC |
21.6~32.0VDC |
43.2~64.0VDC |
Rated 80% output efficiency① |
84.4% |
89.1% |
91.1% |
Maximum rated output efficiency② |
81.3% |
86.8% |
89.7% |
Maximum output efficiency③ |
90.9%(500W) |
94%(500W) |
94%(800W) |
Inrush current at input |
20A@25℃,VIN=12V |
20A@25℃,VIN=24V |
20A@25℃,VIN=48V |
No-load current |
<2.1A |
<0.6A |
<0.5A |
Static loss |
<0.6W@12V |
<0.6W@24V |
<1.8W@48V |
RS485 communication interface |
5VDC/300mA(Non-isolated communication) |
5VDC/300mA(Non-isolated communication) |
5VDC/200mA(Isolated communication) |
Mechanical parameters |
|||
Input terminal |
M10 |
||
Dimensions(L×W×H) |
584×393×175mm |
604×393×175mm |
549×328×175mm |
Installation size |
350×372mm |
350×372mm |
350×307mm |
Mounting hole size |
Φ9mm |
||
Net weight |
32.5kg |
32.7kg |
26.5kg |
Parameter |
NP260-12 |
NP260-22 |
NP400-12 |
NP400-22 |
Continuous output power |
260W@25℃, 200W@45℃ |
400W@25℃, 350W@45℃ |
||
Can withstand instantaneous shock power |
400W |
700W |
||
The output voltage |
220/230VAC(-8%~+3%) |
|||
Output frequency |
50/60Hz±0.2% |
|||
Output waveform |
Pure sine wave |
|||
Output harmonic components |
THD≤3%(Pure resistive load) |
|||
Load power factor |
0.2~1(Load power≤continuous output power) |
|||
Input rated voltage |
12VDC |
24VDC |
12VDC |
24VDC |
Input voltage range |
10.8~16.0VDC |
21.6~32.0VDC |
10.8~16.0VDC |
21.6~32.0VDC |
Rated 80% output efficiency① |
81% |
84% |
81% |
85% |
Maximum rated output efficiency② |
79% |
82% |
79% |
84% |
Maximum output efficiency③ |
89%(80W) |
90%(100W) |
90%(100W) |
91%(100W) |
Inrush current at input |
20A@25℃,VIN=12V |
20A@25℃,VIN=24V |
20A@25℃,VIN=12V |
20A@25℃,VIN=24V |
No-load current |
<0.4A |
<0.3A |
<0.5A |
<0.3A |
Static loss |
<0.3W@12V |
<0.4W@24V |
<0.3W@12V |
<0.4W@24V |
RS485 communication interface |
5VDC/250mA(Non-isolated communication) |
|||
Mechanical parameters |
||||
Input terminal |
M6 |
M6 |
||
Dimensions(L×W×H) |
365×212×97mm |
386×215×99mm |
||
Installation size |
220×193mm |
230×196mm |
||
Mounting hole size |
Φ7mm |
Φ7mm |
||
Net weight |
6.4kg |
6.3kg |
8.1kg |
7.9kg |
Parameter |
NP600-12 |
NP600-22 |
NP800-12 |
NP1000-22 |
NP1000-42 |
Continuous output power |
600W@25℃, 500W@45℃ |
800W@45℃ |
1000W@45℃ |
||
Can withstand instantaneous shock power |
1000W |
1600W |
2000W |
||
The output voltage |
220/230VAC(-8%~+3%) |
220/230VAC(±3%) |
220/230VAC(-8%~+3%) |
220/230VAC(±3%) |
|
Output frequency |
50/60Hz±0.2% |
||||
Output waveform |
Pure sine wave |
||||
Output harmonic components |
THD≤3%(Pure resistive load) |
||||
Load power factor |
0.2~1(Load power≤continuous output power) |
||||
Input rated voltage |
12VDC |
24VDC |
12VDC |
24VDC |
48VDC |
Input voltage range |
10.8~16.0VDC |
21.6~32.0VDC |
10.8~16.0VDC |
21.6~32.0VDC |
43.2~64.0VDC |
Rated 80% output efficiency① |
81% |
85% |
83% |
85% |
90.8% |
Maximum rated output efficiency② |
80% |
83% |
81% |
82% |
89.4% |
Maximum output efficiency③ |
89%(200W) |
92%(160W) |
92%(100W) |
92%(200W) |
94.5%(300W) |
Inrush current at input |
20A@25℃,VIN=12V |
20A@25℃,VIN=24V |
20A@25℃,VIN=12V |
30A@25℃,VIN=24V |
30A@25℃,VIN=48V |
No-load current |
<0.6A |
<0.4A |
<0.6A |
<0.4A |
<0.19A |
Static loss |
<0.3W@12V |
<0.4W@24V |
<0.3W@12V |
<0.4W@24V |
<0.7W@48V |
RS485 communication interface |
5VDC/250mA(Non-isolated communication) |
5VDC/300mA(Isolated communication) |
|||
Mechanical parameters |
|||||
Input terminal |
M8 |
M6 |
M8 |
||
Dimensions(L×W×H) |
428×243×121mm |
475×268×139mm |
452x268x139 |
||
Installation size |
260×220mm |
270×245mm |
270x245 |
||
Mounting hole size |
Φ9mm |
Φ9mm |
Φ9mm |
||
Net weight |
10.4kg |
10.1kg |
13.3kg |
12.7kg |
13.9kg |
Parameter |
NP1200-12 |
NP1200-22 |
NP1500-12 |
NP1500-22 |
Continuous output power |
1200W@25℃, 1000W@45℃ |
1500W@25℃, 1300W@45℃ |
1500W@45℃ |
|
Can withstand instantaneous shock power |
2000W |
3000W |
||
The output voltage |
220/230VAC(-8%~+3%) |
220/230VAC(±3%) |
220/230VAC(-5%~+3%) |
220/230VAC(±3%) |
Output frequency |
50/60Hz±0.2% |
|||
Output waveform |
Pure sine wave |
|||
Output harmonic components |
THD≤3%(Pure resistive load) |
THD≤3%(Pure resistive load) |
THD≤5%(Pure resistive load) |
THD≤3%(Pure resistive load) |
Load power factor |
0.2~1(Load power≤continuous output power) |
|||
Input rated voltage |
12VDC |
24VDC |
12VDC |
24VDC |
Input voltage range |
10.8~16.0VDC |
21.6~32.0VDC |
10.8~16.0VDC |
21.6~32.0VDC |
Rated 80% output efficiency① |
81% |
85% |
84% |
88.5% |
Maximum rated output efficiency② |
78% |
84% |
82% |
87% |
Maximum output efficiency③ |
92%(200W) |
93%(300W) |
90%(400W) |
92%(500W) |
Inrush current at input |
30A@25℃,VIN=12V |
30A@25℃,VIN=24V |
20A@25℃,VIN=12V |
20A@25℃,VIN=24V |
No-load current |
<0.6A |
<0.4A |
<2.0A |
<0.5A |
Static loss |
<0.3W@12V |
<0.4W@24V |
<0.6W@12V |
<0.6W@24V |
RS485 communication interface |
5VDC/250mA(Non-isolated communication) |
5VDC/300mA(Non-isolated communication) |
||
Mechanical parameters |
||||
Input terminal |
M6 |
M10 |
||
Dimensions(L×W×H) |
511×268×139mm |
566×313×145mm |
||
Installation size |
300×245mm |
350×292mm |
||
Mounting hole size |
Φ9mm |
Φ9mm |
||
Net weight |
15.7kg |
15.3kg |
20.3kg |
20.2kg |
Parameter |
NP2000-12 |
NP2000-22 |
NP2000-42 |
Continuous output power |
2000W@45℃ |
||
Can withstand instantaneous shock power |
4000W |
||
The output voltage |
220/230VAC(-5%~+3%) |
||
Output frequency |
50/60Hz±0.2% |
||
Output waveform |
Pure sine wave |
||
Output harmonic components |
THD≤5%(Pure resistive load) |
THD≤3%(Pure resistive load) |
THD≤3%(Pure resistive load) |
Load power factor |
0.2~1(Load power≤continuous output power) |
||
Input rated voltage |
12VDC |
24VDC |
48VDC |
Input voltage range |
10.8~16.0VDC |
21.6~32.0VDC |
43.2~64.0VDC |
Rated 80% output efficiency① |
84.5% |
88% |
89% |
Maximum rated output efficiency② |
82% |
86% |
87% |
Maximum output efficiency③ |
90%(600W) |
93%(500W) |
93%(500W) |
Inrush current at input |
20A@25℃,VIN=12V |
20A@25℃,VIN=24V |
20A@25℃,VIN=48V |
No-load current |
<2.5A |
<0.6A |
<0.3A |
Static loss |
<0.6W@12V |
<0.6W@24V |
<1.8W@48V |
RS485 communication interface |
5VDC/300mA(Non-isolated communication) |
5VDC/300mA(Non-isolated communication) |
5VDC/200mA(Isolated communication) |
Mechanical parameters |
|||
Input terminal |
M10 |
||
Dimensions(L×W×H) |
554×393×175mm |
486×313×145mm |
|
Installation size |
350×372mm |
350×292mm |
|
Mounting hole size |
Φ9mm |
||
Net weight |
29.8kg |
27.6kg |
20.7kg |
Parameter |
NP2500-12 |
NP2500-22 |
NP2500-42 |
Continuous output power |
2500W@45℃ |
||
Can withstand instantaneous shock power |
5000W |
||
The output voltage |
220/230VAC(-8%~+3%) |
220/230VAC(-6%~+3%) |
220/230VAC(±3%) |
Output frequency |
50/60Hz±0.2% |
||
Output waveform |
Pure sine wave |
||
Output harmonic components |
THD≤5%(Pure resistive load) |
THD≤3%(Pure resistive load) |
THD≤3%(Pure resistive load) |
Load power factor |
0.2~1(Load power≤continuous output power) |
||
Input rated voltage |
12VDC |
24VDC |
48VDC |
Input voltage range |
10.8~16.0VDC |
21.6~32.0VDC |
43.2~64.0VDC |
Rated 80% output efficiency① |
87% |
89% |
91.5% |
Maximum rated output efficiency② |
85% |
87% |
90% |
Maximum output efficiency③ |
90%(700W) |
93%(500W) |
94%(800W) |
Inrush current at input |
20A@25℃,VIN=12V |
20A@25℃,VIN=24V |
20A@25℃,VIN=48V |
No-load current |
<3.0A |
<0.8A |
<0.5A |
Static loss |
<0.6W@12V |
<0.6W@24V |
<1.8W@48V |
RS485 communication interface |
5VDC/300mA(Non-isolated communication) |
5VDC/300mA(Non-isolated communication) |
5VDC/200mA(Isolated communication) |
Mechanical parameters |
|||
Input terminal |
M10 |
||
Dimensions(L×W×H) |
584×393×175mm |
604×393×175mm |
549×328×175mm |
Installation size |
350×372mm |
350×372mm |
350×307mm |
Mounting hole size |
Φ9mm |
||
Net weight |
32.0kg |
32.2kg |
25.5kg |
Parameter |
NP3000-22 |
NP3000-42 |
NP3500-42 |
Continuous output power |
3000W@45℃ |
3500W@45℃ |
|
Can withstand instantaneous shock power |
6000W |
7000W |
|
The output voltage |
220/230VAC(-5%~+3%) |
220/230VAC(±3%) |
220/230VAC(±3%) |
Output frequency |
50/60Hz±0.2% |
||
Output waveform |
Pure sine wave |
||
Output harmonic components |
THD≤3%(Pure resistive load) |
||
Load power factor |
0.2~1(Load power≤continuous output power) |
||
Input rated voltage |
24VDC |
48VDC |
48VDC |
Input voltage range |
21.6~32.0VDC |
43.2~64.0VDC |
43.2~64.0VDC |
Rated 80% output efficiency① |
88% |
90% |
90% |
Maximum rated output efficiency② |
86% |
89% |
89% |
Maximum output efficiency③ |
94%(500W) |
94%(900W) |
93%(900W) |
Inrush current at input |
20A@25℃,VIN=24V |
20A@25℃,VIN=48V |
20A@25℃,VIN=48V |
No-load current |
<0.8A |
<0.5A |
<0.5A |
Static loss |
<0.6W@24V |
<1.8W@48V |
<1.8W@48V |
RS485 communication interface |
5VDC/300mA(Non-isolated communication) |
5VDC/200mA(Isolated communication) |
5VDC/200mA(Isolated communication) |
Mechanical parameters |
|||
Input terminal |
M10 |
||
Dimensions(L×W×H) |
649×393×175mm |
599×328×175mm |
579×353×175mm |
Installation size |
350×372mm |
350×307mm |
350×332mm |
Mounting hole size |
Φ9mm |
||
Net weight |
34.0kg |
28.4kg |
32.2kg |
Parameter |
NP4000-22 |
NP4000-42 |
NP5000-42 |
Continuous output power |
4000W@45℃ |
5000W@45℃ |
|
Can withstand instantaneous shock power |
8000W |
10000W |
|
The output voltage |
220/230VAC(±3%) |
||
Output frequency |
50/60Hz±0.2% |
||
Output waveform |
Pure sine wave |
||
Output harmonic components |
THD≤3%(Pure resistive load) |
||
Load power factor |
0.2~1(Load power≤continuous output power) |
||
Input rated voltage |
24VDC |
48VDC |
48VDC |
Input voltage range |
21.6~32.0VDC |
43.2~64.0VDC |
43.2~64.0VDC |
Rated 80% output efficiency① |
89% |
91.5% |
91.5% |
Maximum rated output efficiency② |
86% |
90% |
90% |
Maximum output efficiency③ |
93%(1400W) |
94%(1000W) |
94%(1400W) |
Inrush current at input |
20A@25℃,VIN=24V |
30A@25℃,VIN=48V |
30A@25℃,VIN=48V |
No-load current |
<2.5A |
<0.5A |
<0.5A |
Static loss |
<0.6W@24V |
<1.8W@48V |
<1.8W@48V |
RS485 communication interface |
5VDC/300mA(Non-isolated communication) |
5VDC/200mA(Isolated communication) |
5VDC/200mA(Isolated communication) |
Mechanical parameters |
|||
Input terminal |
M8(4P) |
M10 |
M8(2P) |
Dimensions(L×W×H) |
660×435×210mm |
604×393×175mm |
640×435×210mm |
Installation size |
625×300mm |
350×340mm |
605×300mm |
Mounting hole size |
Φ8.5mm |
Φ9mm |
Φ8.5mm |
Net weight |
43.2kg |
37.0kg |
50.0kg |
Related Products
Please enter your message and we will contact you as soon as possible!